S-114
■ Details of FAN
Type
1
2
3
4
5
6
7
8
9
10
Fan
Laser cooling fan (FM4, front; FM5, rear)
Primary suction fan (FM8, left; FM9, right)
Primary exhaust fan (FM6)
Pre-fixing feeding fan (FM7)
Pre-fixing feeding fan (FM7) low-speed rota-
tion
Delivery assembly exhaust fan 1 (FM1), 2
(FM2), 3 (FM3) high-speed rotation
Delivery assembly exhaust fan 1 (FM1), 2
(FM2), 3 (FM3) low-speed rotation
Delivery lower cooling fan1 (FM19)
Delivery lower cooling fan2 (FM20)
Delivery lower cooling fan3 (FM27)
Delivery colling fan (FM34)
All fans
Control
On for 5 sec, off for 5 sec; then, remains on
continuously.
ON for 5 sec, off for 5 sec; then, on for 5 sec
and stops.
On for 5 sec, off for 5 sec; then, on for 5 sec
and stops.
Rotates at high-speed for 10sec, then, rotates
at low-speed for 10sec, and stops.
On for 5 sec, off for 5 sec; then, operates con-
tinuously.
FM27 rotates for 10sec, thereafter, FM19/20
rotates for 10sec and then stops.
Rotates at high-speed for 10sec;then, rotates
at low-speed for 10sec, and stops.
The cooling fan rotates at high-speed for 5
sec and then at low-speed for 5 sec:
• Delivery assembly exhaust fan 1 (FM1)
• Delivery assembly exhaust fan 2 (FM2)
• Delivery assembly exhaust fan 3 (FM3)
• Pre-fixing feed fan (FM7)
• General delivery fan 1 (FM21)
• General exhaust fan 2 (FM22)
• General exhaust fan 3 (FM 23)
• Delivery cooling fan (FM34)
To stop the operation, turn off the power
switch.
REF.
Press the Stop key to stop the operation, thereby returning to normal state.